Male IC Socket Use Of Improper Presence Of 11 Major Fire Hazards
Aug 18, 2017

Male IC Socket use of improper presence of 11 major fire hazards
  A small Male IC Socket, if not properly used, may lead to major security incidents, the following came to talk about the use of Male IC Socket improper 11 fire hazards.
1, the toilet Male IC Socket to install anti-splash box, to avoid splashing water splashing.
2, Male IC Socket is combusted by the flammable material or dust caused by a short circuit, or installed in a flammable and explosive dangerous place, insert or unplug the plug when the spark caused an explosion fire.
3, plug damage is not timely replacement, with a bare wire head instead of plug use, resulting in short circuit or spark, causing combustible fire.
4, some bedside switch in use after a release, the switch hit the bed frame or wall leaving the outer insulation layer is damaged, most likely cause short circuit.
5, the lamp holder working voltage and operating current and the use of Male IC Socket power does not match, long-term overload, once the temperature is too high will cause a fire. Three male aurora Male IC Socket are 16A large current limit, to meet all the industry and the family of normal electricity. Some other switches are generally 10A current limit, when the family a little more power consumption, it will cause a fire.
6, flat mouth or screw mouth lamp holder or multi-eye Male IC Socket with the wire end of the insulation stripping. Too long, the exposed part of the short circuit; too short, bad conductor contact, contact resistance is too large, overheating caused by fire.
7, the process of installing the lamp holder twist the lamp holder and twist the wire together, or exposed too much core, spread after the other end caused by short-circuit fire.
8, improper installation of the switch, in particular, the switch installed in the combustible object, the lead wire at the lead was scratched, so that the core exposed or water vapor infiltration, resulting in short circuit, or switch off when the arc caused by fire.
9, the distribution board is not into the box, the fuse will be hot when the hot metal particles splashed, so that the following combustible material caused by burning.
10, the home use of combustible gas due to pipeline or valve leakage, so that combustible gas and air mixture to reach the explosion limit, open and close the arc switch without electrical switch, it will produce sparks, causing a fire or explosion. The three male aurora switch applied silver-nickel alloy contacts and sliding rocker, so not only to avoid the arcing, but also greatly extended the life of the switch panel. In this proposal to buy a switch to buy silver-nickel alloy contacts, do not buy sterling silver, aluminum, etc., their melting point is low, easy to melt, more prone to arc.
11, chandelier with the power cord cross section is small and the use of power is too large, so that wire fever.
Many consumers reflect their own Male IC Socket or not installed less, or is the location of the wrong installation, there are models of the wrong model, we all know that the Male IC Socket once the installation is complete, late change, then generally more difficult. The number of electrical appliances in each family is different, the number of natural Male IC Socket can not be consistent. And to determine the number of Male IC Socket needs, you can consider the three factors mentioned above to determine.
After determining the number of Male IC Socket, it is to determine the location of the installation. Lamp switch from the ground in general 1.2m ~ 1.4m (and adult shoulder as high), and installed at the same height, a difference of not more than 5mm; switch position at the same time need to take into account the family's habits. Male IC Socket to determine the location of the installation than the switch to be relatively complex. Electrical appliances and furniture placement and size of the Male IC Socket for the location of the installation is very large.